diff options
-rwxr-xr-x | setup.py | 1 | ||||
-rw-r--r-- | szilagyi/__init__.py | 27 |
2 files changed, 21 insertions, 7 deletions
@@ -5,6 +5,7 @@ from setuptools import setup setup( name="szilagyi", packages=["szilagyi"], + install_requires=["pint"], extra_requires={"plots": ["matplotlib"]}, package_data={"": ["_dataset/*.csv"]}, include_package_data=True, diff --git a/szilagyi/__init__.py b/szilagyi/__init__.py index 3e91936..8d294d7 100644 --- a/szilagyi/__init__.py +++ b/szilagyi/__init__.py @@ -4,25 +4,38 @@ are continuous. The wind-speed at 850 hPa is ignored as the nomogram dictates it There is only one function provided, so the use should be straight-forward. For example:: + >>> import pint >>> import szilagyi - >>> round(szilagyi.calculate_swi(10.5, 24100), 3) + >>> u = pint.UnitRegistry() + >>> round(szilagyi.calculate_swi(10.5 * u.C, 24100 * u.ft), 3) 0.811 - >>> round(szilagyi.calculate_swi(7, 12500), 3) + >>> round(szilagyi.calculate_swi(7 * u.C, 12500 * u.ft), 3) -4.88 """ +from pint import UnitRegistry +from pint.quantity import Quantity + from ._nomogram import calculate_swi as _calculate_swi from ._nomogram import MAX_TEMPERATURE_DIFFERENCE, MAX_CONVECTIVE_CLOUD_DEPTH +_registry = UnitRegistry() + -def calculate_swi(temperature_difference, convective_cloud_depth): +def calculate_swi(temperature_difference: Quantity, convective_cloud_depth: Quantity) -> float: """ - Calculates the Szilagyi Waterspout Index for *temperature_difference* and *convective_cloud_depth*. These are - expected to be expressed in Celsius degrees and feet, respectively. + Calculates the Szilagyi Waterspout Index for *temperature_difference* and *convective_cloud_depth*. - Function will raise ValueError if one of the values is not in range of the original nomogram. The maximum values are - available as MAX_TEMPERATURE_DIFFERENCE and MAX_CONVECTIVE_CLOUD_DEPTH constants. + Function will raise ValueError if input values are not convertible to their expected units or if they are not in range + of the original nomogram. The maximum values are available as MAX_TEMPERATURE_DIFFERENCE and MAX_CONVECTIVE_CLOUD_DEPTH + constants. """ + if not temperature_difference.is_compatible_with(_registry.C): + raise ValueError("temperature_difference must be convertible to Celsius degrees") + if not convective_cloud_depth.is_compatible_with(_registry.ft): + raise ValueError("convective_cloud_depth must be convertible to Feet") + temperature_difference = temperature_difference.m_as(_registry.C) + convective_cloud_depth = convective_cloud_depth.m_as(_registry.ft) if temperature_difference < 0 or temperature_difference > MAX_TEMPERATURE_DIFFERENCE: raise ValueError(f"temperature_difference must be within <0, {MAX_TEMPERATURE_DIFFERENCE}> range") if convective_cloud_depth < 0 or convective_cloud_depth > MAX_CONVECTIVE_CLOUD_DEPTH: |